2. Technology of CO₂ enrichmentTwenty plots (each 1.1 m²) are exposed to
elevated CO₂ (target value of 550 ppm) using a
FACE system with pure CO₂ release. Another 20
plots are used as controls at a current ambient
CO₂ concentration (370 ppm).
Liquid CO₂ is brought in by helicopter biweekly.
CO₂ is then delivered to a control system in the
field equipped with an infrared gas analyzer
(IRGA) for CO₂ measurement, a control PC and an
array of solenoid valves for CO₂ flow control
(see Fig. 2). Four enriched plots are supplied
with CO₂ according to actual CO₂ concentrations
measured within a reference plot.
The pure CO₂ release technology proved suitable
for CO₂ enrichment of natural vegetation at our
remote treeline site. Reliable CO₂ control was
achieved comparable to previous FACE systems with
relatively small fluctuations around the target
CO₂ concentration (see Fig. 4).
Seasonal averages of CO₂ concentrations
(2001-2003; ± SD) were 566 ± 42, 582 ± 35 and 579
± 52 ppm (data analysis courtesy of G. Grun).
|